ALLEN-BRADLEY 1305 AC Drives
The 1305 Adjustable Frequency AC Drive is a variable speed drive designed to control the speed of three-phase AC induction
motors in a variety of demanding applications where flexibility, performance and ease of use are essential. The 1305 Adjustable Frequency AC drive is available with ratings 0.37 to 4 kW (0.5 to 5HP) at 380-460V and 0.37to 2.2 kW (0.5 to 3HP) at 200-230V.
Technical Specifications
- 1305 Drives horsepower ratings range from 0.5-3HP or 0.5-5HP
- Input-voltage range from 200-230V or 380-460V
- Output voltage adjustable from 0V to input voltage for all 1305 Drives
- Operational range from 180-265V or 340-500V
- Typical efficiency for all 1305 Drives is 97.5%
- Output frequency 0.00 to 400.00Hz programable for all 1305 Drives
- SCANport Load maximum is 205 mA for all adapters combined
Troubleshooting your 1305 AC Drive
1305 Fault Descriptions
Name and Fault Number | Description | Suggested Action |
Diag C Lim Fault – F36 | Drive ouptut current exceeded the software [Current Limit] and the [Cur Lim Trip En] parameter was enabled. | Check programming of [Curr Lim Trip En] parameter. Check for excess load, improper DC boost setting, DC brake volts set too high or other causes of excess current. |
Drive → HIM | The check sum read from the HIM’s EEPROM does not match the check sum calculated from the EEPROM data. | Repeat operation. Replace HIM. |
Drive Reset Fault – F22 | May occur on power-up. Caused by having the Start (or Run) Input closed, witht eh Stop input open and [Run On Power Up] = Disabled | Check stop connection located at TB2, terminal 8. |
EEprom Fault – F32 | EEPROM has invalid data or cannot be programmed to valid data | Check cable connection from main control board to power board. Reset to Default Parameters and Cycle power. |
Hz Err Fault – F29 | No valid operating frequency. Possible causes:1. [Maximum Frequency] is less than [Minimum Freq]
2. Skip frequencies and skip bandwith eliminate all operating frequencies. 3. 4-20mA input signal speed reference has been lost or is out of range and [4-20mA Loss Sel] has “Stop-Fault” selected. |
1. Check [Minimum Freq] and [Maximum Freq] parameters.2. Check [Skip Freq 1], [Skip Freq 2], [Skip Freq 3] and [Skip Freq Band] parameters.
3. Check for broken wires, loose connections, or transducer loss at 4-20mA input, TB2. |
Hz Sel Fault – F30 | An unconnected adapter has been selected as the active frequency source. | Connect proper adapter or change active frequency source. |
HIM→Drive | Error 1 – Check sum read from the HIM’s EEPROM does not match check sum calculated from the EEPROM data.Error 2 – The number of parameters in saved profile does not equal master number.
Error 3 – Download was attempted to a different type drive (i.e. 1336 -> 1305). Error 4 – Saved data for parameter not correct for new drive. Error 5 – Drive is running while attempting download |
Repeat operation. Old profile corrupt. Save a new profile. Repeat operation.The last parameter programmed will be displayed on the top line. Verify that all parameters have been programmed. If not, manually program any remaining parameters.
Download can only occur with the same type of drive. Capabilities of drive are different than the master drive. Press Enter to continue download. when download is complete, manually program the parameter where the error occured. Stop drive, then re-run download. |
IPM Current Fault – F44 | The internal power module overcurrent limit has been exceeded. | Inspect for short at the drive output or excessive load conditions on the motor, especially cable capacitance to ground. |
IPM Overtemp Fault – F45 | The internal power module thermal limit has been exceeded. | Inspect for blocked or contaminated heat sink fins. Inspect for proper mounting and spacing. Inspect to ensure that the ambient temperature limit has not been exceeded. |
Max Retries Fault – F33 | Drive unsuccessfully attempted to reset a fault and resume running for the preset number of [Reset/Run Tries]. | Inspect fault buffer for fault code requiring reset. Correct the cause of the fault and manually clear by cycling the stop command or cycling power. |
Motor Mode Fault – F24 | Internal error | Reset your drive to the factory default settings. |
Motor Stall Fault – F6 | The motor has stalled | If the motor is drawing excessive current, the motor load is excessive and will not allow the drive to accelerate to set speed. A longer acceleration tiime or a lighter load may be required. |
Neg Slope Fault – F35 | Drive software detected a portion of the volts/Hertz curve with a negative slope | Inspect drive programming.1. [Base Voltage] parameter must be greater than 1.5 X [Start Boost] |
Network Error* | Network Error 0 – Error 6 Scanport ErrorNetwork Error 7 – Error 9 Communications Error | 1. Pres the “UP” or “DOWN” key to clear the message from the HIM display.2. Unplug the HIM from the cable or drive, then reconnect it.
3. Check for external noise sources. |
Op Error Fault – F11 | [Motor Type] is set to “Sync PM” and [Stop Mode] is set to “DC Brake” | Adjust one of these parameters. DC Braking cannot be used with a synchronous motor. |
Open Pot Fault – F9 | An external pot is connected and the ground lead of the pot is disconnected, creating a potential drive overspeed hazard. | Check the external potentiometer circuit at TB2, terminals 1, 2, and 3 for a disconnected current. |
Overcurrent Fault – F12 | Overcurrent is detected in overcurrent hardware trip circuit. | Check for a short circuit at the drive output or excessive load conditions at the motor. |
Overload Fault – F7 | Internal electronic overload trip. | Excessive motor load. Reduce so that the drive output current does not exceed the % of current set by the [Overload Current] parameter. Reduce [Start Boost] if applicable. Change [Cable Length] to “Long” if applicable. |
Overspeed Fault – F25 | Internal error. | Reset your drive to the factory default settings. |
Overtemperature Fault – F8 | Temperature sensor detects excessive heat. | Inspect for blocked or contaminated heat sink fins. Check for proper mounting and spacing. Inspect to ensure that the ambient temperature limit has not been exceeded. |
ALLEN BRADLEY 1305 AC DRIVE PRODUCT SELECTION
1305 AC Drives | Description |
1305-AA02A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-AA02A-HA1 | 1305-AA02A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA02A-HA2 | 1305-AA02A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA02A-HAP | 1305-AA02A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA03A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-AA03A-HA1 | 1305-AA03A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA03A-HA2 | 1305-AA03A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA03A-HAP | 1305-AA03A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA04A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-AA04A-FR | 1305-AA04A-FR 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V … |
1305-AA04A-HA1 | 1305-AA04A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA04A-HA2 | 1305-AA04A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA04A-HAP | 1305-AA04A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA08A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-AA08A-FR | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-AA08A-HA1 | 1305-AA08A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA08A-HA2 | 1305-AA08A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA08A-HAP | 1305-AA08A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA12A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-AA12A-HA1 | 1305-AA12A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA12A-HA2 | 1305-AA12A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-AA12A-HAP | 1305-AA12A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 200-240V, Single Phase or 200-230V… |
1305-BA01A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA01A-DE | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA01A-HA1 | 1305-BA01A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA01A-HA2 | 1305-BA01A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA01A-HAP | 1305-BA01A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and P… |
1305-BA01A-IT | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA02A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA02A-DE | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA02A-HA1 | 1305-BA02A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA02A-HA2 | 1305-BA02A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA02A-HAP | 1305-BA02A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and P… |
1305-BA03A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA03A-DE | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA03A-FR | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA03A-HA1 | 1305-BA03A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA03A-HA2 | 1305-BA03A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA03A-HAP | 1305-BA03A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and P… |
1305-BA04A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA04A-DE | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA04A-DE-HA2 | 1305-BA04A-DE-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating an… |
1305-BA04A-ES | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA04A-FR | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA04A-HA1 | 1305-BA04A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA04A-HA2 | 1305-BA04A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA04A-HAP | 1305-BA04A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and P… |
1305-BA06A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA06A-DE | 1305-BA06A-DE 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and N/… |
1305-BA06A-ES | 1305-BA06A-ES 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and N/… |
1305-BA06A-HA1 | 1305-BA06A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA06A-HA2 | 1305-BA06A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA06A-HAP | 1305-BA06A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and P… |
1305-BA09A | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA09A-DE | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-BA09A-HA1 | 1305-BA09A-HA1 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA09A-HA2 | 1305-BA09A-HA2 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and H… |
1305-BA09A-HAP | 1305-BA09A-HAP 1305 AC Drives with IP 30 (NEMA Type 1) enclosure, 380-460V, Three Phase rating and P… |
1305-BA09FC-HJ2 | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |
1305-HA02FC-HJ2C | Allen Bradley-DRIVE .5HP 3-PH 230VAC OUT 2.3AMP AB |