Inverter MICROMASTER 430 Drive Technologies – Siemens

Siemens MICROMASTER 430 is the ideal AC drive for pump and fan applications. The integrated PID and pump synchronization functionality make this a cost-effective solution for flow control applications. With advanced features like energy savings mode and customizable v/hz control mode that can be programmed to match pump and fan curves, the MICROMASTER 430 will improve your productivity while saving costs.

Standard Features

  • Customized Operator panel for flow control applications
  • PID process controller
  • Integrated RS 485 communications
  • Optional communication modules include PROFIBUS, CanOpen, DeviceNet™ communication
  • Energy Savings Mode
  • Bypass Mode
  • Belt Break / Pump Dry Detection
  • Configurable I/O
  • Internal Logic Functionality
  • Configuration and programming via keypad, STARTER, or DriveMonitor software

Contact us !We have a good prices and excellent service!

MICROMASTER 430

MICROMASTER 430 Standard Drives

Siemens MICROMASTER 430 is the ideal AC drive for pump and fan applications. The integrated PID and pump synchronization functionality make this a cost-effective solution for flow control applications. With advanced features like energy savings mode and customizable v/hz control mode that can be programmed to match pump and fan curves, the MICROMASTER 430 will improve your productivity while saving costs.

Standard Features

  • Customized Operator panel for flow control applications
  • PID process controller
  • Integrated RS 485 communications
  • Optional communication modules include PROFIBUS, CanOpen, DeviceNet™ communication
  • Energy Savings Mode
  • Bypass Mode
  • Belt Break / Pump Dry Detection
  • Configurable I/O
  • Internal Logic Functionality
  • Configuration and programming via keypad, STARTER, or DriveMonitor software

Technical Information

Voltage and Power Ranges 380-480 V, ± 10%, 3 AC, 10 to 300 HP (7.5 to 250 kW)
Control Types V / Hz, Voltage Boost, Slip Compensation, FCC (Flux Current Control)
Standards UL, cUL, CE, C-Tick
Operating Temperature 0 to +40 °C (+32 to +104 °F)
Degree of Protection IP20

Specialized Applications

  • Pumps
  • Fans
International standards
  • The MICROMASTER 430 inverter complies with the requirements of the EU low-voltage guideline.
  • The MICROMASTER 430 inverter has CE marking.
  • Acc. to UL and c UL certified
  • c-tick

Mechanical features

  • Modular design
  • Operating temperature: –10 °C to +40 °C (+14 °F to +104 °F)
  • Compact housing as a result of high power density
  • Easy cable connection, mains and motor connections are separated for optimum electromagnetic compatibility
  • Detachable operator panels
  • Screwless control terminals on detachable I/O board

SIEMENS MICROMASTER 430 TECHNICAL DATA

TECHNICAL DATA

MICROMASTER 430

Mains voltage and power ranges

380 V to 480 V 3 AC  ±10 %

7.5 kW to 250 kW (variable torque)

Power frequency

47 Hz to 63 Hz

Output frequency

for inverter 7.5 kW to 90 kW

0 … 650 Hz, (limitation to 550 Hz in production to comply with legal requirements) 1)

for inverter 110 kW to 250 kW

0 Hz to 267 Hz

Power factor

≥ 0.95

Inverter efficiency

for inverter 7.5 kW to 90 kW

96 % to 97 %

for inverter 110 kW to 250 kW

97 % to 98 %

(Further information is available on the Internet at:
http://support.automation.siemens.com/WW/view/en/22978972)

Overload capability

for inverter 7.5 kW to 90 kW

Overload current 1.4 x rated output current (i.e. 140 % overload capability) for 3 s and 1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s

for inverter 110 kW to 250 kW

Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 1 s and 1.1 x rated output current (i.e. 110 % overload capability) for 60 s, cycle time 300 s

Inrush current

less than rated input current

Control method

linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic (programmable V/f characteristic); flux current control (FCC); energy saving mode

Pulse frequency

for inverter 7.5 kW to 90 kW

4 kHz (standard)
2 kHz to 16 kHz (in 2-kHz-steps)

for inverter 110 kW to 250 kW

2 kHz (standard)
2 kHz to 4 kHz (in 2-kHz-steps)

Fixed frequencies

15, programmable

Skip frequency ranges

4, programmable

Setpoint resolution

0.01 Hz digital
0.01 Hz serial
10 bit analog

Digital inputs

6 fully programmable isolated digital inputs; switchable PNP/NPN

Analog inputs

2 programmable analog inputs

  • 0 V to 10 V, 0 mA to 20 mA and –10 V to +10 V (AIN1)
  • 0 V to 10 V and 0 mA to 20 mA (AIN2)
  • both can be used as 7th/8th digital input

Relay outputs

3, programmable
30 V DC/5 A (resistive load),
250 V AC/2 A (inductive load)

Analog outputs

2, programmable (0/4 mA to 20 mA)

Serial interfaces

RS-485, option RS-232

Motor cable length

for inverter 7.5 kW to 90 kW

Without output choke

max. 50 m (shielded)
max. 100 m (unshielded)

With output choke

See variant dependent options

for inverter 110 kW to 250 kW

Without output choke

max. 200 m (shielded)
max. 300 m (unshielded)

With output choke

See variant dependent options

Electromagnetic compatibility

for inverter 7.5 kW to 90 kW

Inverter with internal filter Class A available

for inverter without filter

7.5 kW to 15 kW

EMC filter Class B to EN 55 011 available as an option

18.5 kW to 90 kW

EMC filter Class B from Schaffner available as an option

110 kW to 250 kW

EMC filter Class A available as an option

Braking

DC braking, compound braking

Degree of protection

IP20

Operating temperature range

for inverter 7.5 kW to 90 kW

-10 °C to +40 °C (+14 °F to +104 °F)

for inverter 110 kW to 250 kW

0 °C to +40 °C (+32 °F to +104 °F)

Storage temperature

-40 °C to +70 °C (-40 °F to +158 °F)

Relative humidity

95 % (non-condensing)

Installation altitude

for inverter 7.5 kW to 90 kW

up to 1000 m above sea level without derating

for inverter 110 kW to 250 kW

up to 2000 m above sea level without derating

Standard SCCR
(Short Circuit Current Rating) 2)

FSC: 100 kA
FSD, FSE, FSF, FSFX, FSGX: 65 kA

Protection features for

undervoltage, overvoltage, overload, earth faults, short-circuits, stall prevention, locked motor protection, motor overtemperature, inverter overtemperature, parameter change protection

Conformity with standards

for inverter 7.5 kW to 90 kW

 UL, cUL, CE, c-tick

for inverter 110 kW to 250 kW

UL available soon, cULavailable soon, CE

CE marking

Conformity with low-voltage directive 73/23/EEC

Cooling-air volumetric flow required, dimensions and weights (without options)

Frame size (FS)

Cooling-air volumetric flow required (l/s)/(CFM)

H x W x D (mm)

Weight, approx. (kg)

C

54.9/116.3

245 x 185 x 195

5.7

D

2 x 54.9/2 x 116.3

520 x 275 x 245

17

E

2 x 54.9/2 x 116.3

650 x 275 x 245

22

F without filter

150/317.79

850 x 350 x 320

56

F with filter

150/317.79

1150 x 350 x 320

75

FX

225/478.13

1400 x 326 x 356

116

GX

440/935

1533 x 326 x 545

174

CFM:
Cubic Feet per Minute

Excellent Service

Quick quote and quick delivery for each order/request.

Quick Delivery

Fast shipping and Quick Delivery use DHL/UPS/TNT

Lowest Prices

Save you 30% of the purchasing cost

Global Company

We are an international company in the UK and HK