SIEMENS standard CPUs SIPLUS S7-300 CPU 315-2 PN/DP

SIPLUS S7-300 CPU 315-2 PN/DP Overview

SIMATIC Micro Memory Card required for operation of CPU.

  • The CPU with medium-sized program memory and quantity frameworks
  • High processing performance in binary and floating-point arithmetic
  • Used as central controller in production lines with central and distributed I/O
  • Component Based Automation (CBA) on PROFINET
  • PROFINET proxy for intelligent devices on PROFIBUS DP in Component Based Automation (CBA)
  • PROFINET IO Controller for operating distributed I/O on PROFINET
  • PROFINET interface with 2-port switch
  • Combined MPI/PROFIBUS DP master/slave interface
  • Isochronous mode on PROFIBUS
Note:

SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added.

Product No. / Product Description Listprice / Your price
6AG1315-2EH14-2AY0
SIPLUS S7-300 CPU 315-2PN/DP -25…+60 °C with conformity with EN 50155 T1 Kat 1 Kl A/B based on 6ES7315-2EH14-0AB0 . Central processing unit with 384 KB work memory, 1st interface MPI/DP 12Mbit/ s, 2nd interface Ethernet PROFINET, with 2-port switch, Micro Memory Card required
6AG1315-2EH14-7AB0
SIPLUS S7-300 CPU315-2PN/DP -25 … +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7315-2EH14-0AB0 . CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

Contact us !We have a good prices and excellent service!

SIPLUS S7-300 CPU 315-2 PN/DP Application

The SIPLUS S7-300 CPU 315-2 PN/DP is a CPU with medium-sized program memory. It is used in plants containing distributed automation structures in addition to a centralized I/O. It can be implemented as a PROFINET IO controller and as a standard PROFIBUS DP master in the SIMATIC S7-300. The 315-2 PN/DP CPU can also be used as distributed intelligence (PROFIBUS DP slave or PROFINET I-Device).

The SIPLUS S7-300 CPU 315-2 PN/DP is an ideal platform for simple software-implemented technological tasks, e.g.:

  • Motion control with Easy Motion Control.
  • Implementation of control engineering tasks using STEP 7 blocks or runtime software Standard PID Control/Modular PID Control.

An extended process diagnosis is possible by using SIMATIC S7-PDIAG.

The integrated communication options of the CPU enable networked automation solutions to be implemented without additional components.


SIPLUS S7-300 CPU 315-2 PN/DP Design

The SIPLUS S7-300 CPU 315-2 PN/DP is equipped with the following:

  • Microprocessor;
    the processor can handle execution times of approx. 50 ns per binary instruction and 450 ns per floating-point instruction.
  • 384 KB main memory (corresponds to approx. 128 K instructions);
    the extensive work memory for for program components relevant to execution offers sufficient space for user programs. SIMATIC Micro Memory Cards (8 MB max.) as load memory for the program also allow the project to be stored in the CPU (complete with symbols and comments) and can be used for data archiving and recipe management.
  • Flexible expansion;
    max. 32 modules (4-tier configuration).
  • Combined MPI/DP interface;
    the first integrated MPI/DP interface can establish up to 16 connections simultaneously to the S7-300/400 or connections to PGs, PCs and OPs. One of the connections is permanently reserved for programming devices and one for OPs.
    The MPI supports simple networking of up to 32 CPUs over “Global data communication”.
    This interface can be reconfigured from MPI interface to DP interface.
    PROFIBUS DP interface:
    The DP interface can be used as a DP master or as a DP slave. PROFIBUS DP slaves can be operated isochronously on this interface. The PROFIBUS DP V1 standard is fully supported. This increases the scope of DP V1 standard slaves in terms of diagnostics and parameterization capability.
  • Ethernet interface;
    the second integral interface of the CPU 315-2 PN/DP is a PROFINET interface with a 2-port switch, based on Ethernet TCP/IP.
    It supports the following protocols:

    • S7 communication for data communication between SIMATIC controllers;
    • PG/OP communication for programming, startup and diagnostics through STEP 7;
    • PG/OP communication for interfacing to HMI and SCADA;
    • Open TCP/IP, UDP and ISO-on-TCP (RFC1006) communication over PROFINET;
    • SIMATIC NET OPC-Server for communication with other controllers and I/O devices with own CPU

SIPLUS S7-300 CPU 315-2 PN/DP Function

  • Password protection;
    a password concept protects the user program from unauthorized access.
  • Block encryption;
    the functions (FCs) and function blocks (FBs) can be stored in the CPU in encrypted form by means of S7-Block Privacy to protect the know-how of the application.
  • Diagnostics buffer;
    the last 500 error and interrupt events are stored in a buffer for diagnostic purposes.
  • Maintenance-free data backup;
    the CPU automatically saves all data (up to 128 KB) in case of a power failure so that the data are available again unchanged when the power returns.

Parameterizable properties

The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

  • General;
    definition of the name, system ID and location ID.
  • Startup;
    definition of the startup characteristics of the CPU and the monitoring time
  • Synchronous cycle interrupts;
    setting of DP master system, process image partition number, and delay time
  • Cycle/clock memory;
    specification of the maximum cycle time and load. Setting of the clock memory address. Enabling prioritized HMI communication
  • Retentivity;
    setting retentive areas
  • Clock interrupts;
    setting the start date, start time and periodicity
  • Watchdog interrupts;
    setting of periodicity
  • System diagnostics;
    determining handling and scope of the diagnostic alarms
  • Clock;
    setting the type of synchronization in the AS or on the MPI
  • Protection level;
    specifying the access rights to program and data
  • Communication;
    reservation of connection resources
  • Web;
    settings for the Web server of the CPU
  • MPI/PROFIBUS DP interface;
    setting the interface type. Determining node addresses. Parameterizing the operating mode and configuring the transfer areas in the case of PROFIBUS DP. Parameterizing the time synchronization
  • PROFINET interface;
    setting of addresses. Parameterizing the PROFINET properties, the I-Device functionality, the type of synchronization on PROFINET, the time synchronization using NTP procedure, the media redundancy, and the KeepAlive function. Parameterizing port 1 and port 2

SIPLUS S7-300 CPU 315-2 PN/DP Technical specifications

Article number

6AG1315-2EH14-2AY0

6AG1315-2EH14-7AB0

SIPLUS S7-300 CPU315-2PN/DP EN50155

SIPLUS S7-300 CPU315-2PN/DP

General information

HW functional status

01

01

Firmware version

V3.2

V3.2

Engineering with

  • ● Programming package

STEP 7 V5.5 or higher

STEP 7 V5.5 or higher

Supply voltage

Rated value (DC)

  • ● 24 V DC

Yes; A power supply according to EN 50155 shall be used

Yes

permissible range, lower limit (DC)

20.4 V

20.4 V

permissible range, upper limit (DC)

28.8 V

28.8 V

external protection for power supply lines (recommendation)

2 A min.

2 A min.

Mains buffering

  • ● Mains/voltage failure stored energy time

5 ms

5 ms

  • ● Repeat rate, min.

1 s

1 s

Input current

Current consumption (rated value)

750 mA

750 mA

Current consumption (in no-load operation), typ.

150 mA

150 mA

Inrush current, typ.

4 A

4 A

I²t

1 A²·s

1 A²·s

Power loss

Power loss, typ.

4.65 W

4.65 W

Memory

Work memory

  • ● integrated

384 kbyte

384 kbyte

  • ● expandable

No

No

  • ● Size of retentive memory for retentive data blocks

128 kbyte

128 kbyte

Load memory

  • ● Plug-in (MMC)

Yes

Yes

  • ● Plug-in (MMC), max.

8 Mbyte

8 Mbyte

  • ● Data management on MMC (after last programming), min.

10 y

10 y

Backup

  • ● present

Yes; Guaranteed by MMC (maintenance-free)

Yes; Guaranteed by MMC (maintenance-free)

  • ● without battery

Yes; Program and data

Yes; Program and data

CPU processing times

for bit operations, typ.

0.05 µs

0.05 µs

for word operations, typ.

0.09 µs

0.09 µs

for fixed point arithmetic, typ.

0.12 µs

0.12 µs

for floating point arithmetic, typ.

0.45 µs

0.45 µs

CPU-blocks

Number of blocks (total)

1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

  • ● Number, max.

1 024; Number range: 1 to 16000

1 024; Number range: 1 to 16000

  • ● Size, max.

64 kbyte

64 kbyte

FB

  • ● Number, max.

1 024; Number range: 0 to 7999

1 024; Number range: 0 to 7999

  • ● Size, max.

64 kbyte

64 kbyte

FC

  • ● Number, max.

1 024; Number range: 0 to 7999

1 024; Number range: 0 to 7999

  • ● Size, max.

64 kbyte

64 kbyte

OB

  • ● Size, max.

64 kbyte

64 kbyte

  • ● Number of free cycle OBs

1; OB 1

1; OB 1

  • ● Number of time alarm OBs

1; OB 10

1; OB 10

  • ● Number of delay alarm OBs

2; OB 20, 21

2; OB 20, 21

  • ● Number of cyclic interrupt OBs

4; OB 32, 33, 34, 35

4; OB 32, 33, 34, 35

  • ● Number of process alarm OBs

1; OB 40

1; OB 40

  • ● Number of DPV1 alarm OBs

3; OB 55, 56, 57

3; OB 55, 56, 57

  • ● Number of isochronous mode OBs

1; OB 61

1; OB 61

  • ● Number of startup OBs

1; OB 100

1; OB 100

  • ● Number of asynchronous error OBs

6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)

6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)

  • ● Number of synchronous error OBs

2; OB 121, 122

2; OB 121, 122

Nesting depth

  • ● per priority class

16

16

  • ● additional within an error OB

4

4

Counters, timers and their retentivity

S7 counter

  • ● Number

256

256

Retentivity

  • — adjustable

Yes

Yes

  • — lower limit

0

0

  • — upper limit

255

255

  • — preset

Z 0 to Z 7

Z 0 to Z 7

Counting range

  • — can be set

Yes

Yes

  • — lower limit

0

0

  • — upper limit

999

999

Excellent Service

Quick quote and quick delivery for each order/request.

Quick Delivery

Fast shipping and Quick Delivery use DHL/UPS/TNT

Lowest Prices

Save you 30% of the purchasing cost

Global Company

We are an international company in the UK and HK